High Voltage DC Contactor

High Voltage DC Contactor DH20
Small volume, light weight, seal structure for the main contact,working under inert gas protection, high breaking capacity,with no...
More
High Voltage DC Contactor DH50C
50A Contact switch capacity, Small volume; ·A set of bridge type N.O.contacts contact circuit has  "+", "-" polarity;...
More
High Voltage DC Contactor DH100
·DC contactor high current Application:Telecom equipment、Solar system、 Engineering machinery、Electromobile、Electric vehicle、Chargi...
More
High Voltage DC Contactor DH200H
500A rating current (Continues current), 200A breaking current,small volume; ·Switch DC loads at both low and high voltage from 1...
More
High Voltage DC Contactor DH250L
Non-polar type contact circuit is non-polar and can be connected in any direction. ·Coil power is very low,coil maintain power Ma...
More
High Voltage DC Contactor DH250
250A Contact switch capacity, Small volume; ·This series covers both polar and non-polar series.Polar type has a set of bridge N....
More
High Voltage DC Contactor DH200
·Coil power is very low,coil maintain power Max 1.8W;Non-polar type contact circuit is non-polar and can be connected in any direc...
More
High Voltage DC Contactor DH150
·Safety Approvals:UL、CE、 CCC ·Comply with the ROHS ·This series covers both polar and non-polar series.Polar type has a set of b...
More
High Voltage DC Contactor DH300
300A Contact switch capacity, Small volume; ·A set of bridge type N.O.contacts& a set of N.O. aux contact, contact circuit has  "...
More
High Voltage DC Contactor DHC20
400A Contact switch capacity,Small volume; ·Coil with energy saving device,the max holding power consumption is 4.5W....
More
High Voltage DC Contactor DHC40
·Using ceramic brazing technology,the contact part is sealed with hydrogen gas.The contact does not oxidize,can quickly cut off in...
More
High Voltage DC Contactor DHC100
Min applicable load (Resistive load): 1A/12VDC. Max switch current: 1000A(300VDC)1 cycle...
More
High Voltage DC Contactor DHC150
Max switch current: 1500A(300VDC)1 time. Max switch voltage: 1000VDC...
More
High Voltage DC Contactor DHC200
·Coil with energy saving device,the max hold in power consumption is 4.5W. 200A Contact switch capacity,Small volume;...
More
High Voltage DC Contactor DHC250
Contact form: 1H(SPST-NO); Rated load(Resistive load): 250A; Min applicable load (Resistive load): 1A/12VDC; Max switch current: 2...
More
Versatile Applications for High Voltage DC Contactors
Our high voltage DC contactors are engineered for a wide range of applications, ensuring reliability and efficiency in demanding environments.
tu-1.jpg

Dual Gun Charging Post
tu-2.jpg

Centralized Power Distribution
tu-3.jpg

Switching Module
tu-4.jpg

On-board PDU
Practical Case Demonstration
tu-5.jpg

European Home Storage Project

tu-6.jpg

Charging Pile Project

tu-7.jpg

Charging project

tu-8.jpg

Supercharging project

tu-9.jpg

Spruce 120kw Project

Frequently Asked Questions

Q1: What is the rated voltage range of your HV/LV DC contactors? Can they support 1500V DC PV/ESS systems?

A: Our DC contactors cover a wide voltage range from 12V to 1500V DC. The 1500V series is specifically designed for PV energy storage and high-voltage boxes, complying with IEC 60947-4-1.

Q2: What is the protection rating? Can they be used in humid/dusty environments?

A: With an IP67 protection rating, it is fully dust-tight and waterproof, making it ideal for outdoor charging piles and offshore wind power energy storage applications.

Q3: How do DC contactors achieve arc extinction?

Answer:
DC contactors primarily use two key mechanisms to extinguish arcs effectively:
1. Magnetic Blow-out Arc Extinguishing:
The contactor stretches the electric arc as much as possible within the limited space of the arc chamber. This makes it difficult for the DC arc to sustain itself, leading to its eventual break.
2. Protective Gas:
When an arc is generated, the protective gas inside the chamber is difficult to ionize. This property effectively enhances the dielectric strength of the space, helping to quench the arc.

 

Q4: What is the temperature rise capability of your product?

A: When using the specified copper busbar, our product's temperature rise is kept within ≤65K. Upon request, we can provide corresponding test reports, including those under normal and high ambient temperatures. If specific current levels or copper busbars are required, we can conduct preliminary tests.

Q5: Can your product meet our operating conditions of **A / *V?

A: Our product has undergone electrical life tests for make and break operations at the rated current and voltage. The number of operations is documented in our reports, which we can organize and provide. Additionally, we have relevant certification reports. Furthermore, we can conduct preliminary tests based on customer requirements.

GET A QUOTE

GET IN TOUCH NOW
Captcha Code
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All